Comparison of PI Controller, Fuzzy controller and Practical Swam Optimization for Dual Three Phase Induction Motors Drives Control Based on Indirect Field Vector Oriented Method
Keywords:
Indirect Field Oriented Control, Five Leg Inverter, DZS, Dual IM, Practical swarm optimization
Abstract
To reduce the cost and the system complexity in power applications, voltage source five-leg modulation inverter of space vector pulse width (FLI) is designed to drive dual induction motors. This paper presents independent control of dual induction motor fed by five-leg inverter. The control conducted through Indirect field- is applied separately by each motor. With three controllers; PI-controller; fuzzy controller; practical swarm optimization. Generation of the signal of switching for FLI a double space vector pulse width modulator is utilized and a double zero-sequence modulation technique (DZS) is employed to generate the modulation signals. Finally, a comparison of three presented controller are carried out for the two motors operate under different operation condition was the result that proved that dual induction motor independently can be put under control of the FLI with FLC.
Section
Articles
Copyright (c) 2021 Transylvanian Review
This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.